Cycle Segment Charts (continued)
Programming
Details
Use Up or Down to change. Start key is enter or advance
00 or 02 - 30 Segment time: 00 to skip, or any time between 0 and 30 minutes
HFIL CFIL BFIL Fill temperature: Hot, Cold, or Warm (both fill)
LOLE or HILE Select Fill level, Low or High
SUP0 - SUP7 Select Supply 0-7 (0 for no supply during the step)
00, 75 - 200
00, 25 - 93
SPIN flases for 1 sec
TIME flases for 1 sec
00 or 30 - 120
Select time for spin: 30 - 120 seconds. 00 for no spin.
Note: Supply 4 and 7 are only availble if enabled in Setup
Note: Heat is only available if enabled in Setup
Display
UASH
Enter temperature: 75-200 deg F, 25-93 deg C. 00 for no heat.
Select 00 if you have programmed a Flushing Prewash
Wash Segment
Details
Use Up or Down to change. Start key is enter or advance
drin or srin (1) Select Rinse Method: Dilution Rinse or Spray Rinse
00 or 02 - 30 (2) Segment time: 00 to skip, or any time between 0 and 30 min
HFIL CFIL BFIL (3) Fill temperature: Hot, Cold, or Warm (both fill)
LOLE or HILE (4) Select Fill level, Low or High
SUP0 - SUP7 (5) Select Supply 0-7 (0 for no supply during the step)
00, 75 - 200
00, 25 - 93
SPIN flases for 1 sec
TIME flases for 1 sec
00 or 30 - 120
(7) Select time for spin: 30 - 120 seconds. 00 for no spin.
Note: Heat is only available if enabled in Setup
Note: If Spray Rinse is selected for the segment, steps 3 to 6 are skipped.
fil1 fil2 fil3 fil4 fil5
(6) Enter temperature: 75-200 deg F, 25-93 deg C. 00 for no heat.
Select 00 if you have programmed a Flushing Prewash
Note: Supply 4 and 7 are only availble if enabled in Setup
Fill Segments (Fill 1 through Fill 5)